Transformer Protection Fuse (HT HRC)

Transformer protection fuse from Panickker, covering 3.3 to 36 kV, up to 500 A and 25, 40 or 63 kA short circuit capacity, made in India since 1974.

Fuse Gear

Transformer Protection Fuse (HT HRC)

Technical specifications

ApplicationTransformer primary-side short-circuit protection (back-up fuse)
Voltage3.3, 7.2, 12, 24 and 36 kV
CurrentUp to 500 A
Short circuit capacity25, 40, 63 kA
TypeBS / IEC / DIN

Standards: BS / IEC / DIN

What is a transformer protection fuse?

A transformer protection fuse is a high-voltage fuse fitted on the primary side of a distribution or power transformer to clear short-circuit faults. Panickker describes its transformer protection fuses as back-up fuses that take care of short circuit protection. If a fault occurs inside the transformer or its connected circuit, the fuse interrupts the fault current, isolates the faulty section and stops the fault spreading to the rest of the network.

The current rating of the fuse is chosen so that it carries the transformer’s inrush current without blowing unnecessarily.

Panickker transformer protection fuse ratings

Panickker transformer protection fuse ratings follow the HT HRC fuse range:

  • Voltage: 3.3, 7.2, 12, 24 and 36 kV
  • Current: up to 500 A
  • Short circuit capacity: 25, 40 or 63 kA, depending on the rating
  • Types: BS / IEC / DIN

The full range is on the HT HRC fuses 3.3–36 kV page, and the PDF is in the catalogues. Contact our engineers for the exact rating for your application.

Where it is used

Transformer protection fuses are used on the primary side of distribution and power transformers in industrial plants, substations and utility networks, usually together with a load break switch or other switching device. They help reduce downtime by limiting the damage from a transformer fault.

How to select the right rating

The right fuse depends on the transformer and the system it feeds. To get a recommendation, share these details with our engineers:

  • Transformer kVA rating and primary (system) voltage
  • Inrush (magnetising) current and how the transformer is switched
  • The switching device the fuse works with, and any upstream protection to coordinate with
  • Preferred fuse type: BS, IEC or DIN

Time-current curves and charts are on the fuse selection charts page. Related: HT HRC fuses and PT fuses. Request a quote for a transformer protection fuse.

Why Panickker

Panickker Switchgear Pvt. Ltd. has manufactured switchgear and fuses since 1974 at its own factory in Sriperumbudur, near Chennai, with design and manufacturing done in-house. FUSEGEAR HRC fuses are made to BS, IEC and DIN types. The company is certified to ISO 9001:2015, and the certificate scope includes HT HRC fuses, semiconductor fuses and LT HRC fuses, as well as ISO 14001:2015.

Questions about Transformer Protection Fuse (HT HRC)

What size HT fuse is needed for a 1000 kVA, 11 kV transformer?

The fuse is selected from the transformer kVA and primary voltage so that it carries full-load and inrush current without blowing and still clears a fault. For a 1000 kVA, 11 kV transformer, share the details with our engineers or refer to the transformer charts on the fuse selection charts page. Contact our engineers for the exact rating for your application.

Is a transformer protection fuse a back-up fuse?

Panickker states that its transformer protection fuses are back-up fuses that take care of short circuit protection, and that their current ratings are designed to allow for transformer inrush current.

What voltages and short circuit capacities do Panickker transformer fuses cover?

The HT HRC range covers 3.3, 7.2, 12, 24 and 36 kV, with current ratings up to 500 A and short circuit capacities of 25, 40 and 63 kA, in BS, IEC and DIN types.

Why must inrush current be considered when choosing a transformer fuse?

When a transformer is energised it draws a short, high magnetising current. If the fuse rating is too low it can blow on switching, so the rating must allow for inrush while still protecting against faults.

Related products in Fuse Gear

Motor Protection Fuse (HT HRC)

Motor protection fuse from Panickker HT HRC range: 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA short circuit capacity,…

Application
High-voltage motor circuit short-circuit protection
Voltage
3.3, 7.2, 12, 24 and 36 kV

Capacitor Protection Fuse (HT HRC)

Capacitor protection fuse from Panickker for capacitor banks, covering 3.3 to 36 kV and up to 500 A in the HT HRC range, made…

Application
Capacitor bank overcurrent and fault protection
Voltage
3.3, 7.2, 12, 24 and 36 kV

Back-up Fuse (HT HRC, Current-Limiting)

Back-up fuse from Panickker: current-limiting HT HRC fuses for 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA, made in…

Application
Short-circuit (fault current) protection, current-limiting
Voltage
3.3, 7.2, 12, 24 and 36 kV

Need Transformer Protection Fuse (HT HRC)?

Send your voltage, current rating and quantity. We will respond with a quotation.

Get a quote