Manufacturing HT/LT switchgear and HRC fuses since 1974

Back-up Fuse (HT HRC, Current-Limiting)

Back-up fuse from Panickker: current-limiting HT HRC fuses for 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA, made in India since 1974.

Fuse Gear

Back-up Fuse (HT HRC, Current-Limiting)

Technical specifications

ApplicationShort-circuit (fault current) protection, current-limiting
Voltage3.3, 7.2, 12, 24 and 36 kV
CurrentUp to 500 A
Short circuit capacity25, 40, 63 kA
TypeBS / IEC / DIN

Standards: BS / IEC / DIN

What is a back-up fuse?

A back-up fuse is a current-limiting fuse that clears high fault currents, typically used with a switch or contactor that handles the low overcurrents. The fuse takes over when the fault current is too high for the switching device to break safely.

Panickker describes its transformer protection fuses as back-up fuses that take care of short circuit protection. They are HT HRC (High Rupturing Capacity) fuses, made to interrupt high fault currents quickly and safely.

Panickker back-up fuse ratings

Panickker back-up fuse ratings follow the HT HRC fuse range:

  • Voltage: 3.3, 7.2, 12, 24 and 36 kV
  • Current: up to 500 A
  • Short circuit capacity: 25, 40 or 63 kA, depending on the rating
  • Types: BS / IEC / DIN

The full range is on the HT HRC fuses 3.3–36 kV page, and the PDF is in the catalogues. Contact our engineers for the exact rating for your application.

Where it is used

Back-up fuses are used on high-voltage circuits that need short-circuit protection, such as transformer primaries, motor starters and capacitor banks, usually together with a load break switch, contactor or starter.

How to select the right rating

A back-up fuse must be matched to the device it works with. Please share:

  • System voltage and the equipment protected (transformer kVA, motor or capacitor bank details)
  • The switch or contactor used, and its breaking capacity
  • Required fault level (short circuit capacity)
  • Preferred type: BS, IEC or DIN

Our engineers will coordinate the fuse with your switching device.

Time-current curves and charts are on the fuse selection charts page. Related: HT HRC fuses and PT fuses. Request a quote for a back-up fuse.

Why Panickker

Panickker Switchgear Pvt. Ltd. has manufactured switchgear and fuses since 1974 at its own factory in Sriperumbudur, near Chennai, with design and manufacturing done in-house. FUSEGEAR HRC fuses are made to BS, IEC and DIN types. The company is certified to ISO 9001:2015, and the certificate scope includes HT HRC fuses, semiconductor fuses and LT HRC fuses, as well as ISO 14001:2015.

Questions about Back-up Fuse (HT HRC, Current-Limiting)

What is the difference between a back-up fuse and a full-range fuse?

A back-up fuse clears high fault currents only and relies on a switch or contactor for low overcurrents. A full-range fuse clears the whole range of overcurrents. The choice depends on the application.

Are Panickker transformer protection fuses back-up fuses?

Yes. Panickker describes its transformer protection fuses as back-up fuses that take care of short circuit protection.

What ratings do Panickker HT HRC back-up fuses have?

3.3, 7.2, 12, 24 and 36 kV, up to 500 A, with 25, 40 and 63 kA short circuit capacity, in BS, IEC and DIN types.

How is a back-up fuse coordinated with a contactor or switch?

The fuse and the switching device are chosen so that every fault current is cleared by one of them. Send the switch or contactor details to our engineers for coordination.

Related products in Fuse Gear

Transformer Protection Fuse (HT HRC)

Transformer protection fuse from Panickker, covering 3.3 to 36 kV, up to 500 A and 25, 40 or 63 kA short circuit capacity, made…

Application
Transformer primary-side short-circuit protection (back-up fuse)
Voltage
3.3, 7.2, 12, 24 and 36 kV

Motor Protection Fuse (HT HRC)

Motor protection fuse from Panickker HT HRC range: 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA short circuit capacity,…

Application
High-voltage motor circuit short-circuit protection
Voltage
3.3, 7.2, 12, 24 and 36 kV

Capacitor Protection Fuse (HT HRC)

Capacitor protection fuse from Panickker for capacitor banks, covering 3.3 to 36 kV and up to 500 A in the HT HRC range, made…

Application
Capacitor bank overcurrent and fault protection
Voltage
3.3, 7.2, 12, 24 and 36 kV

Need Back-up Fuse (HT HRC, Current-Limiting)?

Send your voltage, current rating and quantity. We will respond with a quotation.

Get a quote