Motor Protection Fuse (HT HRC)

Motor protection fuse from Panickker HT HRC range: 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA short circuit capacity, made in India since 1974.

Fuse Gear

Motor Protection Fuse (HT HRC)

Technical specifications

ApplicationHigh-voltage motor circuit short-circuit protection
Voltage3.3, 7.2, 12, 24 and 36 kV
CurrentUp to 500 A
Short circuit capacity25, 40, 63 kA
TypeBS / IEC / DIN

Standards: BS / IEC / DIN

What is a motor protection fuse?

A motor protection fuse is a current-limiting HT HRC fuse used in a high-voltage motor starter or control circuit to clear short-circuit faults. It is normally used with a contactor or starter that handles normal running overloads, while the fuse deals with the high fault currents.

Panickker states that its fuses can withstand the high starting current of motors, so circuits are not interrupted unnecessarily. They are compact and space-saving, which helps keep motor control panel layouts tidy.

Panickker motor protection fuse ratings

Panickker motor protection fuse ratings follow the HT HRC fuse range:

  • Voltage: 3.3, 7.2, 12, 24 and 36 kV
  • Current: up to 500 A
  • Short circuit capacity: 25, 40 or 63 kA, depending on the rating
  • Types: BS / IEC / DIN

The full range is on the HT HRC fuses 3.3–36 kV page, and the PDF is in the catalogues. Contact our engineers for the exact rating for your application.

Where it is used

Motor protection fuses are fitted in high-voltage motor control panels and starters for industrial drives such as pumps, compressors and fans. Fault current is cleared quickly, which limits damage to the motor, cables and starter.

How to select the right rating

Choosing the fuse depends on the motor and how it is started. Please share:

  • Motor voltage, kW or HP rating and full-load current
  • Starting method (direct on line, star-delta, soft starter) and starting current and time
  • Number of starts per hour
  • Contactor or starter used, and its breaking capacity

A motor curve is available on the fuse selection charts page.

Time-current curves and charts are on the fuse selection charts page. Related: HT HRC fuses and PT fuses. Request a quote for a motor protection fuse.

Why Panickker

Panickker Switchgear Pvt. Ltd. has manufactured switchgear and fuses since 1974 at its own factory in Sriperumbudur, near Chennai, with design and manufacturing done in-house. FUSEGEAR HRC fuses are made to BS, IEC and DIN types. The company is certified to ISO 9001:2015, and the certificate scope includes HT HRC fuses, semiconductor fuses and LT HRC fuses, as well as ISO 14001:2015.

Questions about Motor Protection Fuse (HT HRC)

What fuse should I use for an HT motor?

The fuse is selected from the motor voltage, full-load current, starting current and starting time, and the contactor it works with. Share these with our engineers. Contact our engineers for the exact rating for your application.

Can a motor protection fuse handle motor starting current?

Panickker states that its fuses can withstand the high starting current of motors and avoid unnecessary interruptions of the circuit. The exact rating still depends on the starting method and duration.

Do I still need a contactor or overload relay with a motor fuse?

Yes. A fuse clears short-circuit faults. Normal running overloads are handled by the starter, contactor or overload relay, so the two are chosen to work together.

What voltage range do Panickker HT motor fuses cover?

The HT HRC range covers 3.3, 7.2, 12, 24 and 36 kV, up to 500 A, with 25, 40 and 63 kA short circuit capacity, in BS, IEC and DIN types.

Related products in Fuse Gear

Transformer Protection Fuse (HT HRC)

Transformer protection fuse from Panickker, covering 3.3 to 36 kV, up to 500 A and 25, 40 or 63 kA short circuit capacity, made…

Application
Transformer primary-side short-circuit protection (back-up fuse)
Voltage
3.3, 7.2, 12, 24 and 36 kV

Capacitor Protection Fuse (HT HRC)

Capacitor protection fuse from Panickker for capacitor banks, covering 3.3 to 36 kV and up to 500 A in the HT HRC range, made…

Application
Capacitor bank overcurrent and fault protection
Voltage
3.3, 7.2, 12, 24 and 36 kV

Back-up Fuse (HT HRC, Current-Limiting)

Back-up fuse from Panickker: current-limiting HT HRC fuses for 3.3 to 36 kV, up to 500 A, 25, 40 or 63 kA, made in…

Application
Short-circuit (fault current) protection, current-limiting
Voltage
3.3, 7.2, 12, 24 and 36 kV

Need Motor Protection Fuse (HT HRC)?

Send your voltage, current rating and quantity. We will respond with a quotation.

Get a quote